KEWO SG600 Series Solar Pump Drives/Inverters
SG600 Solar pump drives advantages:
KewoSG600 solar pump drive is positioned in environmental-friendly and economical PV market, the product is applicable to PV pumping system, replaces water storage with electric storage and needs no battery modules. The direct current generated by solar modules is input to the inverter and then converted into the alternating current to drive various pumps directly. Additionally, the output frequency is adjustable in real time according to sunlight intensity change.
Fully automatic system using variable speed drive compatible with AC, 3-phase, submersible and surface mount pumps, and high efficiency PMSM Pumps. The system is composed of a PV generator, a pump and a solar pump drive. Based on the design philosophy that it is more efficient to store water rather than electricity, there is no energy storing device such as storage battery in the system. The system is prepared to be combined with a elevated water storage, e.g. water tower or an uphill tank installation.
Specification:
150 to 450VDC input, 220-240VAC output, 0.75 to 3.7kw
250 to 800VDC input, 380-480VAC output, 0.75 to 355kw
Descriptions and Features
Ø Maximum power point tracking (MPPT) with fast response speed and stable operation efficiency> 99%;
Ø Suits for most 3 phase AC pumps and AC PMSM high efficiency pumps.
Ø The working voltage of solar panel can set by manual or MPPT automatically tracking
Ø Compatible with dual power input, AC grid and DC power supply input.
Ø Built in automatic sleep-wake up function,
Ø Dry run (under load ) protection
Ø Motor maximum current protection
Ø Low input power protection
Ø Lowest stop frequency protection
Ø The PQ (power/flow) performance curve enables calculating the flow output from the pump
Ø Digital control for fully automatic operation, data storage and protective functions
Ø Intelligent power module (IPM) for the main circuit
Ø LED display operating panel and support remote control
Ø Low water probe sensor, and water level control function
Ø Strong lightning protection
Ambient temperature for using: -10 to +50˚C
Protection features
It is provide kinds of protection function for pumps and inverters such as Dry run protection (under load protection), High voltage surge, Low input voltage, Open motor circuit, Short circuit, Over heat, Earth fault, Phase missing, lowest running, water tank level...
Models and specification
SN | Models | Rate current | Output voltage ( 3PH VAC) | Applicable for pumps | MPPT voltage (VDC) |
Mini type 2S series : 150 to 450 VDC or 220/240VAC input, Vmp 310V,Voc 380V | |||||
1 | SG600-2S-0K7GB-M | 3.8A | 0-240VAC | 0.75KW | 260 to 375 |
2 | SG600-2S-1K5GB-M | 7A | 0-240VAC | 1.5KW | 260 to 375 |
3 | SG600-2S-2K2GB-M | 9A | 0-240VAC | 2.2kw | 260 to 375 |
Mini type 4T series :4T,250 to 800 VDC or 380/ 440VAC input, Vmp520, Voc650 | |||||
1 | SG600-4T-0K7GB-M | 2.3A | 380V-440V | 0.75KW | 486 to 750 |
2 | SG600-4T-1K5GB-M | 3.8A | 380V-440V | 1.5KW | 486 to 750 |
3 | SG600-4T-2K2GB-M | 5.1A | 380V-440V | 2.2KW | 486 to 750 |
4 | SG600-4T-4K0GB-M | 9A | 380V-440V | 4.0KW | 486 to 750 |
General type: 2S, 150 to 450 VDC or 220/ 240VAC input, Vmp 310, Voc380 | |||||
7 | SG600-2S-0K7GB | 3.8A | 220V/240V | 0.75KW | 260 to 375 |
8 | SG600-2S-1K5GB | 7A | 220V/240V | 1.5KW | 260 to 375 |
9 | SG600-2S-2K2GB | 9A | 220V/240V | 2.2KW | 260 to 375 |
10 | SG600-2S-4K0GB | 17A | 220V/240V | 4.0KW | 260 to 375 |
General type: 4T,250/350 to 800 VDC or 380/ 440VAC input, Vmp520, Voc650 | |||||
11 | SG600-4T-0K7GB | 2.3A | 380V-440V | 0.75KW | 486 to 750 |
12 | SG600-4T-1K5GB | 3.8A | 380V-440V | 1.5KW | 486 to 750 |
13 | SG600-4T-2K2GB | 5.1A | 380V-440V | 2.2KW | 486 to 750 |
14 | SG600-4T-4K0GB | 9A | 380V-440V | 4.0KW | 486 to 750 |
15 | SG600-4T-5K5GB | 13A | 380V-440V | 5.5KW | 486 to 750 |
16 | SG600-4T-7K5GB | 17A | 380V-440V | 7.5KW | 486 to 750 |
17 | SG600-4T-011GB | 25A | 380V-440V | 11KW | 486 to 750 |
18 | SG600-4T-015GB | 32A | 380V-440V | 15KW | 486 to 750 |
19 | SG600-4T-018GB | 37A | 380V-440V | 18KW | 486 to 750 |
20 | SG600-4T-022GB | 45A | 380V-440V | 22KW | 486 to 750 |
21 | SG600-4T-030G | 60A | 380V-440V | 30KW | 486 to 750 |
22 | SG600-4T-037G | 75A | 380V-440V | 37KW | 486 to 750 |
23 | SG600-4T-045G | 91A | 380V-440V | 45KW | 486 to 750 |
24 | SG600-4T-055G | 110A | 380V-440V | 55KW | 486 to 750 |
25 | SG600-4T-075G | 150A | 380V-440V | 75KW | 486 to 750 |
26 | SG600-4T-090G | 180A | 380V-440V | 90KW | 486 to 750 |
27 | SG600-4T-110G | 220A | 380V-440V | 110KW | 486 to 750 |
28 | SG600-4T-132G | 260A | 380V-440V | 132KW | 486 to 750 |
29 | SG600-4T-160G | 320A | 380V-440V | 160kw | 486 to 750 |
30 | SG600-4T-**G | ** | 380V-440V | 200-400 | 486 to 750 |
**Solar pump inverter specification when PE-00=1&2 | |
Recommended MPPT voltage range |
Vmp 131 to 350 VDC for 1s (80V to 350VDC input, 3PH 110 to 220VAC output) Vmp 260 to 355VDC for 2S/ 2T ( 150V to 350VDC input, 3PH 220 to 240VAC output) Vmp 486 to 650 VDC for 4T ( 250V to 800VDC input, 3PH 380 to 460VAC output) |
Recommended input Voc and Vmpp voltage |
Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps Voc 380(VDC), Vmpp 310(VDC) for 2S model or 220V AC pumps Voc 650(VDC), Vmpp 520(VDC) for 4T model or 380V AC pumps |
Motor type | Control for permanent magnet synchronous motor and asynchronous motor pumps. |
Rated output voltage | 1/3-Phase,110V/160V/220V. 3-phase, 220V/380V/460V |
Output frequency range | 0~maximum frequency 600Hz. |
MPPT efficiency | Above 99.0%, |
Ambient temperature range | G-type for submersible pumps, 150% rated current for 60s, 180% rated current for 2s . P type for general pumps, 120% rated current for 60s, 150% rated current for 2s |
Solar pump control special performance | MPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum current protection, flow calculating, energy generated calculating and water tank level detected |
Protection function | Phase loss protection, phase short circuit protection, ground to phase circuit protection , input and output short circuit protection. Stall protection, lightning protection |
Protection degree | IP20, Air force cooling |
Running mode | MPPT or CVT |
Altitude | Below 1000m; above 1000m, derated 1% for every additional 100m. |
Enhanced version of AC drive | CE, Design based on vector control motor AC drive, more specification please refer to S600 or S600 vector control drive operation manual |
Technical specification of variable frequency inverter when PE00=0(solar pump disable) | |
voltage, frequency | 1 phase 220V, 3 phase, 220V,380V, 660V, 0-50/60Hz |
Control mode |
0: VF control ; 1: Open loop vector control mode 2: Close loop vector control mode |
Maximum frequency | 0-320Hz in vector control mode, 0~3200Hz in VF control mode |
Multiple-functions | PID Control, Carrier Frequency Adjustable, Current Limiter, Speed Search, Momentary Power Loss Restart,16 Step Speed (Max), 3-Wire connection, Slip Compensation, Frequency Jump, DC braking, Upper/Lower Frequency, Torque control, Compatible for PMSM and IM, built in RS485, counting, fault information checking, fully fault protection function, frequency combination reference. |