KEWO is a top manufacturer of AC drives, variable speed drive, Solar Pump Inverter,Soft Stater, Speed Controller...  
Tel:86-0755-23283620, 
MP:86-13725501611 
Mail:service@kewodrive.com, Skye:liyucheng0211


  
Product center -->Index > Medium-voltage vfd 660v/1140v/3300v > SD3000 Medium voltage vfd > Medium voltage vfd

Medium voltage vfd

Medium voltage vfd
 

Medium-voltage vfd are widely used in which the fields of electric power, iron and steel, petroleum, mining, chemical, cement, automobiles, and utilities.


Feature:
1. Substantial reduction of harmonic current on power source side
SD3200 suppresses the harmonics by using a multi-pulse diode rectification system (12 to 60 pulses),thereby substantially reducing the generation of harmonics in comparison with previous models. The harmonic generation level stipulated in IEEE 519 (1992) is satisfied. This inverter is ideal for power sources.




2. Total inverter effi ciency as high as approximate 97%
a). Because an output transformer is unnecessary, inherent losses are eliminated.
b). Multi-level PWM control minimizes switching loss.
c). Because the harmonic current on the power source side is reduced, the primary winding of the input transformer
has a reduced harmonic losses.
Total inverter efficiency curve (including input transformer)
 
3. Source power factor as high as 95% or more
a). Due to full-wave rectifi cation with multi-phase diodes,operation is allowed with the source power factor (power factor on power source side) set at a high level.
b). A phase advancing capacitor and a DC reactor for improving the source power factor are unnecessary.
c). A smaller power capacity suffices for inverter operation.
4. High-reliability
a) . Higher equipment reliability is achieved by reducing the number of inverter cells by using a single-phase,3-level inverter, etc..
b).  Stable operation is maintained despite load fluctuations, by the simple sensor-less vector control function.
c).  The control device has a 32-bit MPU for quick response and high-accuracy.
5. Vector control
 Vector control with a speed sensor is available (as an option) for equipment having high speed and torque accuracy requirements. (option)
6. Easy maintenance
a). The inverter is air-cooled, requiring no cooling water.
b). Start/stop operation, parameter setting, fault display and data monitoring are performed on the touch panel with simple loader functions.
c). Simple, built-in auto-tuning functions facilitate testing and adjustment.
d). Fault diagnoses are easily performed.
e). A dry-type input transformer is adopted. 

It has several advantages as following:
* Three-level drive technology, lower output harmonics, waveform closer to sine wave, lower motor heating, longer motor workinglife
*High performance for driving permanent magnet synchronous motor and AC asynchronous motor
* Compatible with 6 pulse, 12 pulse, 18 pulse, 24 pulse, multiple voltage input modes, allowing grid voltage range from 85% to 115%
* V/f control and high-performance vector control can be provided to achieve two-quadrant and four-quadrant operation, saving energy and reducing consumption;
* The larger starting torque to easy move the load, soft start and soft stop to eliminate the mechanical and electrical impact, to extend the service life of the equipment; 150% starting torque is available when 1Hz reaching.
* With CAN, Rs485 and other communication interfaces, it can realize communication with the host computer, realize the centralized control operation of multiple devices, and transfer the operation data to the ground dispatching room for remote supervision.
* Multi-channel digital, analog I/O interface
* Compatible with European control mode; capable of master-slave control of multi-machine dragging device
* Power balance during runing (no need to install encoder) and synchronous speed driving
* It has perfect protection functions such as overcurrent, overload, short circuit, phase loss, leakage lockout, overvoltage, undervoltage, overheating and other protection functions.
 
The main advantages of the three-level inverter:
1) Simple structure and small size;
2) Compared with the two levels, the device can achieve 2 times the voltage output with the same voltage level;
3) Reduce the common mode voltage of the motor;
4) Reduce common mode interference to the power grid;
5) It is convenient to realize the two-way flow of energy and the four-quadrant operation of the motor;
6) The output du/dt is reduced by half compared to the two levels;
7) Compared with the two levels, the number of phase voltage output levels increases and the output harmonics decrease.
 

Technical specification 

Technical specification 
Items Specification
Control 
mode
Control mode  V/F control       Sensorless Vector    
control 1
Sensorless Vector   
 control 2
  Close loop vector control
Starting torque 1Hz 150% 0.5Hz 150% 0.25Hz 150% 180% under 0Hz
Speed adjust range ** 1:50 1:200 1:500
speed stabilizing
precision
±0.1% ±0.3% ±0.05% ±0.02%
Torque precision NO NO Yes Yes
Motor type General induction motor,permanent magnet synchronous motor (PMSM)

Function  
 design
Output volage 3 electric level with low harmonic
Highest frequency General vector control :400Hz  V/f control:4000Hz
frequency resolution Digital setting: 0.01Hz  analog setting: maximum×0.025%
carrier frequency 0.5K~16KHz, the carrier frequency can be adjust by temperature automatically
Frequency reference 
setting method
Digital of Control panel, analog AI1, AI2, potentionmeter of control panel, UP/DN
control, communication, PLC pulse frequency
Accel./decel. characteristic Linear curve and S curve accel. /decel. mode, range of time: 0.0 to 65000S.
V/F curve 3 mode: linear, multiple points, N Power
V/F separation 2 times separation: totally separation, half separation
DC braking DC braking frequency: 0.0 to 300Hz, DC braking current: 0.0% to 100%
Braking unit Built in braking unit up to 15kw, optional is 18.5kw to 75kw, external built in for 
above 93kw.
Jog function Job frequency range: 0.0 to 50.0Hz, the accel. and decel. time of Jog
Configuration PID Easy to perform pressure, flow, temperature close loop control
PLC  multiple speed To achieve 16 segment speed running through built in PLC or terminal control
Common Dc bus * Multiple inverters use one DC bus for energy balance.
Auto voltage regulation (AVR)  Enable to keep output voltage constant when grid fluctuation
Over load tolerance capability     G type model: 150% rated current for 60s, 180% rated current for 2s,
P type Model: 120% rated current for 60s, 150% rated current for 3s.
stall control when over 
current, over voltage
Carry out limiting automation for running current, voltage to prevent over current
 over voltage frequently
Fast current limit function minimize the IGBT module broken to protect the inverter, maximum reduce the 
over current fault.
Torque limit and torque 
control
"Excavator" characteristics , torque limit automatically during motor running. 
Torque control is available in close loop vector control mode.
 
Items Specification
features friendly interface Display Hello when power on.
Multiple function key MK
.F 
button
It can set for Forward Jog, reverse Jog, forward/reverse switch
Timing control function A total running time and total running time calculating
Motor over heat
 protection
Accepting motor temperature sensor signal input via AI1 terminals.
Command source Control panel, control terminals, series communication, switch freely.
Frequency source Digital setting, analog current/voltage, pulse setting, serial communication, main 
and auxiliary combination.
Protection function Short circuit detect after power on, input/output phase missing, over voltage, over
current, under voltage, over heat, over load protection.
Environment Application site Indoor, free of exposure to sunlight, no dusty, no corrosive, no inflammable gas, 
no oil and water vapor, and water dipping
Altitude Lower 1000m
environment temperature -10℃~+40℃, power derated for 40~50℃, rated current derated 1% for 1℃increasing.
Humidity Less than 95%, no water condense.
Storage -40~+70℃



Wiring
Multiple digital input, 2 analog input
2 analog output, 2 relay output,
Rs485 and CAN bus interface



Model list
SD3000-37G-T11-ASDA
SD3000 stand for products name
37G stand for rated of power, 37kw
T11 stand for input voltage range, T6: 3PH, 660VAC input, T11: 3PH, 1140VAC, T33: 3PH 3300VAC
ASDA stand for function description,
 
SD3000 series 1140V VFD model list
Series Model list Rated Power (kw) Input current  (A) Output current (A) Input reactor DC Reactor Output Reactor
1 SD3000-37G-T11-ASDA 37 20 23   7.3mh/ 25A 1mh/25A
2 SD3000-45G-T11-ASDA 45 26 28   5.6mh/ 32A 0.8mh/28A
3 SD3000-55G-T11-ASDA 55 34 36   4.2mh/ 42A 0.62mh/36A
4 SD3000-75G-T11-ASDA 55 47 50   3mh/ 58A 0.45mh/50A
5 SD3000-90G-T11-ASDA 90 56 60   2.6mh/ 69A 0.38mh/60A
6 SD3000-110G-T11-ASDA 110 68 73   2.2mh/ 85A 0.3mh/73A
7 SD3000-132G-T11-ASDA 132 82 85   1.78mh/100A 0.26mh/85A
8 SD3000-160G-T11-ASDA 160 98 104   1.5mh/ 120A 0.22mh/104A
9 SD3000-200G-T11-ASDA 200 122 128   1.2mh/ 150A 170mh/128A
10 SD3000-250G-T11-ASDA 250 150 160   0.97mh/ 185A 140mh/160A
11 SD3000-315G-T11-ASDA 315 185 195   0.79mh/ 230A 115mh/195A
12 SD3000-400G-T11-ASDA 400 235 250   0.62mh/ 285A 90mh/250A
13 SD3000-500G-T11-ASDA 500 300 310   0.5mh/ 370A 72mh/310A
14 SD3000-560G-T11-ASDA 560 355 350 0.22mh/ 355A   64mh/350A
15 SD3000-630G-T11-ASDA 630 380 395 0.19mh/ 380A   57mh/395A
16 SD3000-710G-T11-ASDA 710 430 450 0.17mh/ 430A   50mh/450A
17 SD3000-800G-T11-ASDA 800 480 500 0.15mh/ 480A   45mh/500A
18 SD3000-1000G-T11-ASDA 1000 600 520 0.12mh/ 600A   36mh/620A
               
SD3000 series 3300V VFD model list
Series Model list Rated Power Input current Output current Input reactor Output Reactor  
1 SD3000-800G-T33-ASDA 800 166 173 1.2mH/170A 0.6h/180A  
2 SD3000-1000G-T33-ASDA 1000 208 216 1mH/210A 0.48h/220A  
3 SD3000-1250G-T33-ASDA 1250 259 270 0.8mH/260A 0.39h/270A  
4 SD3000-1500G-T33-ASDA 1500 311 324 0.67mH/320A 0.32h/320A  
5 SD3000-2000G-T33-ASDA 2000 415 433 0.5mH/420A 0.24h/420A  
6 SD3000-3000G-T33-ASDA 3000 623 649 0.34mH/630A 0.16h/630A  
SD3000 series 660V VFD model list
Series Model list Rated Power (KW) Input current  (A) Output current (A) Input reactor Output Reactor  
1 SD3000-1000G-T66-ASDA 1000 91 95 4mH/100A 2mH/100A  
2 SD3000-1500G-T66-ASDA 1500 114 119 3.3mH/120A 1.6mH/120A  
3 SD3000-2000G-T66-ASDA 2000 143 149 2.7mH/150A 1.3mH/150A  
4 SD3000-2500G-T66-ASDA 2500 171 178 2.2mH/180A 1mH/180A  
5 SD3000-3000G-T66-ASDA 3000 228 238 1.7mH/240A 0.8mH/240A  
6 SD3000-5000G-T66-ASDA 5000 342 357 1.1mH/360A 0.6mH/360A  
 
 Application.
Construction Materials                         
< 
Kiln head cooling fans
< Kiln tail heating fans
< Grinders
< Cement rotary kilns


Petrochemical Mining
< Catalytic cracking unit
< Hydrogenation compressor
< Oil and gas transmission device
< Blowers/pumps/pelletizer


Mining
< Belt conveyers
< Grinders
< Mine air circulation blowers


Iron and steel
< Blast fumace blowers
< Primary/secondary dust blowers
< Dry quenched coke circulation blower
< High-pressure phosphorus ejector pump
< Blowers/water pumps
< Crusher


Electric power
< Induced draft fan/forced draught fan
< Primary/secondary blowers 
< Condensation pumps
< Recirculation pumps
< Feed pumps


Others
< Water conservancy, utilities (pumps)  
< Sugaring (mill)
< Test crew
< Internal mixer

 
 
 



















Prev:end Next:end
More than 20 years experience for motor AC drive, solar pump inverter